Solinst 410 Peristaltic Pump
Peristaltic Pump Design The Solinst Peristaltic Pump features a clear pump head that allows quick, convenient inspection of the pump head tubing before and during operation. The pump head cover is easy to remove for cleaning or replacing the tubing. The pump head tubing guides are designed to keep the tubing in place during ... Retrieve Content
Versilic Silicone Tubing - Shop.peripump.eu
IMPORTANT: It is the user’s responsibility to ensure the suitability and safety of Saint-Gobain Performance Plastics tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application. ... Doc Viewer
TYGON E-LFL - Shop.peripump.eu
Including 1,000 hours of peristaltic pump tubing life at 0 psi back pressure, low particulate spallation and chemical resistance as the old Tygon® LFL tubing. Tygon® Tubing Provides Optimal Peristaltic Pump Performance Crystal-clear Tygon ® E-LFL tubing is formulated specifically for use in peristaltic pump applications. ... Document Viewer
Geopump Peristaltic Pumps
• Disposable and dedicated tubing means con-trolled costs and no decontamination issues OPERATION Geopump™ Peristaltic Pump Series I with EZ-load 2 pump head (optional) and dispos-a-filter capsule Geopump™ Peristaltic Pump Series II with EZ-load 2 pump head (optional), 5 ft tubing, carrying case and power cord ... Fetch Full Source
Featuring Learn & Repeat™ For Fantastic Productivity!
Pump from a reservoir through replaceable continuous tubing. Pump never comes into contact with fluid. Continuous Pumping. Up to 775 mL/min. Model: PERI-HEAD-KIT-YG4 Green with 4 Rollers (included with the NE-9000G) PharMed® Tubing 1/16”ID x 3/16”OD x 1/16” Wall (5 feet) ... Retrieve Full Source
PARI Vios Nebulizer System Instructional DVD - YouTube
Watch more about how to use your new PARI Vios Nebulizer Compressor System. See how this technology works or how to set-up your device. To purchase a new PARI Vios, please visit our website at ... View Video
The Geneva Mechanism - YouTube
YouTube TV - No long term contract Loading Unlimited DVR storage space. Live TV from 60+ channels. No cable box required. Cancel anytime. Working No thanks Try it free. Find ... View Video
Minerva.union.edu
Sample pump Wash well Internal standard Wash well drain Spray chamber drain Peri pump dilution factor ISTD Pump tubes Area % From calculator web site, above Area ratio from geometry Not used, gravity drain instead Agilent tubing. Author: Kurt Hollocher Last modified by: Kurt Hollocher ... Access Full Source
The Most Durable And Dependable Fluoroelastomer Tubing
GORE™ High-Resilience Tubing Style 400 is a unique composite Style 400 tubing allows users to fully realize the benefits of peri- fewer changeouts and recalibrations so you can pump media with more security and confidence than ever before. 120% 100% 80% 60% 40% 20% 0% ... Access Content
Pierre Robin Syndrome - Wikipedia
Pierre Robin syndrome (abbreviated to PRS, and also known as Pierre Robin sequence, Pierre Robin malformation, Pierre Robin anomaly or Pierre Robin anomalad) is a congenital condition of facial abnormalities in humans. ... Read Article
Care And Use Guide. - Bluelab.com
Individual pump calibration and pump priming. 4 metres / 13 feet of acid / alkaline resistant food grade tubing for dosing pH correction solution. 3x 4 metres / 13 feet per pump of tubing for dosing nutrient stock solution. Replaceable peristaltic pumps and tubing. ... Fetch This Document
A Beginner’s Guide To ICP-MS - Eal.ucmerced.edu
Mally pumped at ~1 mL/min via a peri-staltic pump into the nebulizer. A peri-staltic pump is a small pump with lots of minirollers that rotate at the same speed. The constant motion and pressure of the rollers on the pump tubing feed the sam-ple to the nebulizer. The benefit of a peri-staltic pump is that it ensures a constant ... Retrieve Document
Oils 7400 And Oils 7600 Stirring Autosamplers
Tubing cartridge, Pharmed Peri-Pump tubing cartridge, Stirrer rod for oils, Stirrer rod for coolants, and 24 feet of 1/8” Superthane tubing 32-0342-044 Rinse/Drain Tubing Hookup Kit 7 foot piece of 1/8” ID (2 pieces per kit) Chemical Resistant Tygon 2375 (Coolants) Tygon Fuel and Lubricant tubing (Oils) Superthane Tubing (Oils) 32-0374-047 ... Access Full Source
Combined Presentation Website - Immucor
•Peri-Pump •Syringes • Probe tubing and other tubing • Probe Splash Guard – Tip: Maximize instrument performance by inspecting these items during monthly maintenance • Fluid reservoirs are removed allowing for inspection of syringes and peri-pump • Instrument cover is removed to wipe down the probe block allowing for ... Document Viewer
PERIFUSION SYSTEM MODEL No: PERI-4 - Biorep
1 PERI-TUB-12 Two-Stop Tygon Tubing Set (pack of 12) 1 PERI-TUB-040 Silicone Tubing (50 ft) and B- the peristaltic pump tubing, which provides the precise resolution needed in perifusion experiments. A set of each type is included with this machine. ... Document Viewer
TROUBLESHOOTING ICP SPECTROMETERS - Geicp.com
TROUBLESHOOTING ICP SPECTROMETERS Glass Expansion February 2014 Newsletter, “Troubleshooting Guide for ICP Peri pump & tubing. Nebulizer. Spray Chamber. Torch/injector. RF System. RF coil. Power Amplifier. Recirculator. Optics. Windows& lenses. Focusing optics. ... Fetch Doc
Sample Introduction For ICP-MS And ICP-OES
• PTFE tubing going from the sipper to the peristaltic pump tubing • Peristaltic pump tubing • PTFE tubing going from the peri-staltic pump tubing to the nebulizer • Spray chamber • Torch The main difficulty that analysts typical-ly experience with introduction system failure is that of connections between components. The connections ... Fetch Here
323 PERISTALTIC PUMP - U V Process
This pump is ideal for pumping shear-sensitive fluids, sludges, slurries, viscous fluids, and aggressive acids and caustics. Virtually maintenance-free, this pump has no expensive seals, check valves, diaphragms, or rotors to leak, clog, corrode, and replace. This reduces spare parts inventory. It accepts thick wall tubing which ... Fetch Document
ANALYZER MODELS CIBA CORNING (BAYER) 550/664/278
019819 cc tubing kit, “a” 021347 cc tubing kit, “c” 02134d cc tubing kit, “d” 023319 cc tubing kit, “e” for syringe 023679 cc tubing kit, “b” 024023 cc tube assy, peri pump in/out 11835 cc dowel pin, cuvette feed 128000 cc motor assy, peri pump 134000 cc board assy, lamp/ted rfb 1453x1f cc sensor, edge detector 156000 cc ... View Doc
5990-8182EN 7700 Supplies Quick Reference Guide - HPST
Drain tubing (tubing between peri-pump tubing and drain tank) G1820-65515 Tygon tubing, 3 m (for drain to drain tank) G3280-60077 Drain tubing kit (tubing between spray chamber and peri-pump, includes two connectors, bushing and tubing) G1833-65411 Torch Part No. Torch (quartz), 2.5 mm id G3280-80001 Torch (quartz), 1.5 mm id taper type for use ... Access Content
“Peri” Dosage Pumps For Reliable Dosage of The arrow on the clear pump head points to the discharge tubing and the discharge line should be run to the desired dose injection point and terminated with the injection fitting supplied. 5. Push fit the rigid grey PVC tubing, and run ... Document Viewer
Tygon Tubing Permeability Coefficients For Peristaltic Pump ...
Saint-Gobain Performance Plastics Permeability Coefficients For Peristaltic Pump Tubings Permeability Coefficient = Amount of gas (cm3) x tubing wall thickness (cm) Surface area of tubing I.D. (cm2) x time (seconds) x pressure drop across tubing wall (cmHg) Tygon® LFL 563 ... Read Here
No comments:
Post a Comment